The Series 8900 Analyzer provides direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride in ambient air. This instrument is utilized for remediation and Super Fund sites and to monitor workplace exposure limits.

The Series 8900 Analyzer for Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride employs a flame ionization detector (FID) as the sensing element. A dual column configuration with timed backflush to vent is used to strip off moisture and heavier hydrocarbons. A pre-cut column is used in series with the analytical column. At sample injection a fixed volume of sample is carried to the pre-cut column. Backflush is timed so that only the Methyl Ethyl Ketone, Chloroform, Carbon Tetrachloride and other similar components are eluted to the analytical column. Contaminants on the pre-cut column are backflushed to vent. The chemicals are separated from potentially interfering components on the analytical column and elute to the detector for analysis.
Unit of Measure

Applications

N/A Measurement at Superfund sites during remediation

  • Monitoring workplace exposure limits.

  • Features

    N/A

  • Direct measurement of Methyl Ethyl Ketone, Chloroform and Carbon Tetrachloride
  • Interference free response
  • Automatic calibration for unattended operation
  • Automatic baseline adjustment for long-term stability
  • Analog output ranges are user selectable
  • Multipoint sampling options
  • RS-232 and optional LAN

  • Specifications

    Analysis Time

    N/A <360 seconds

    Detector

    N/A Flame ionization detector (FID)

    Column

    N/A Capillary

    Oven Temperature

    N/A 70ºC, Nominal

    Carrier Gas

    N/A Hydrogen, 13 cc/min, Nominal

    Lower Detection Limit

    N/A <5 ppm

    Accuracy

    N/A 1% of Full-scale

    Precision

    N/A 2% of Measured Value

    Span Drift (24HR)

    N/A <2% of Full-scale

    Sample Flow Rate

    N/A 250 - 500 cc/min, typical

    Output

    N/A Analog: (1) 0-20ma or 4-20ma loop power supplied, isolated. Selectable for: gas concentration, unintegrated detector signal. Options for up to 20 additional programmable 0-20ma, 4-20ma or voltage outputs: 0-1V, 0-5V, or 0-10V.
    Digital: RS-232, optional Local Area Network

    Relays

    N/A (5) User programmable relays for concentration and diagnostic alarms (1A @ 30Vdc). Options for up to 32 additional relays available.

    Inputs

    N/A Optional digital input board for 3 contact closure inputs. Supports start analysis, start calibration, and analyze calibration gas sample.